Climate Change Data Portal
DOI | 10.1115/1.4041881 |
Experimental Evaluation on Low Global Warming Potential HFO-1336mzz-Z as an Alternative to HCFC-123 and HFC-245fa | |
Wang, Shikuan1,2; Guo, Zhikai3; Han, Xiaohong1; Xu, Xiangguo1; Wang, Qin1; Deng, Shiming2; Chen, Guangming1 | |
发表日期 | 2019 |
ISSN | 1948-5085 |
EISSN | 1948-5093 |
卷号 | 11期号:3 |
英文摘要 | HFO-1336mzz-Z with low global warming potential (GWP) was considered as a promising alternative of HCFC-123, HFC-245fa in air conditioning (AC) and heat pump (HP), respectively. In order to understand the operation performances of HFO-1336mzz-Z and HCFC-123, HFC-245fa in different working conditions, an experimental setup for testing the refrigeration cycle performance was built. The cycle performances of HFO-1336mzz-Z and HCFC-123 in AC conditions, HFO-1336mzz-Z and HFC-245fa in HP conditions were investigated by experiment. It was found in AC conditions, the discharge temperatures for the systems with HFO-1336mzz-Z and HCFC-123 were lower than 115 degrees C, the cooling capacity of the system with HF0-1336rnzz-Z was 27% less than that with HCFC123 at least, and the coefficient of performance (COP) of the system with HFO-1336mzzZ was 0.1 lower than that with HCFC-123 ; in HP conditions, the discharge temperature with HFO-1336mzz-Z was lower than that with HFC-245fa, the former was never over 115 degrees C while the latter was up to 126 degrees C, the power input to the compressor with HFO1336mzz-Z was 20% less than that with HFC-245fa in the same HP conditions, the heating capacity of the system with HFO-1336mzz-Z was 30-40% less than that with HFC-245fa. |
WOS研究方向 | Thermodynamics ; Engineering |
来源期刊 | JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS |
文献类型 | 期刊论文 |
条目标识符 | http://gcip.llas.ac.cn/handle/2XKMVOVA/98262 |
作者单位 | 1.Zhejiang Univ, Inst Refrigerat & Cryogen, Key Lab Refrigerat & Cryogen Technol Zhejiang Pro, Hangzhou 310027, Zhejiang, Peoples R China; 2.Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China; 3.Zhejiang Res Inst Chem Ind, Hangzhou 310023, Zhejiang, Peoples R China |
推荐引用方式 GB/T 7714 | Wang, Shikuan,Guo, Zhikai,Han, Xiaohong,et al. Experimental Evaluation on Low Global Warming Potential HFO-1336mzz-Z as an Alternative to HCFC-123 and HFC-245fa[J],2019,11(3). |
APA | Wang, Shikuan.,Guo, Zhikai.,Han, Xiaohong.,Xu, Xiangguo.,Wang, Qin.,...&Chen, Guangming.(2019).Experimental Evaluation on Low Global Warming Potential HFO-1336mzz-Z as an Alternative to HCFC-123 and HFC-245fa.JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS,11(3). |
MLA | Wang, Shikuan,et al."Experimental Evaluation on Low Global Warming Potential HFO-1336mzz-Z as an Alternative to HCFC-123 and HFC-245fa".JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS 11.3(2019). |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。