Climate Change Data Portal
DOI | 10.1016/j.buildenv.2018.12.056 |
Influence of ICHTC correlations on the thermal characterization of facades using the quantitative internal infrared thermography method | |
Bienvenido-Huertas, David1; Bermudez, Javier2; Moyano, Juan J.1; Marin, David1 | |
发表日期 | 2019 |
ISSN | 0360-1323 |
EISSN | 1873-684X |
卷号 | 149页码:512-525 |
英文摘要 | The thermal characterization of facades of the existing building stock is essential to establish optimal energy conservation measures. There are different methods to characterize thermal properties of facades. The quantitative internal infrared thermography method is among those most developed. Given the existing differences in the scientific literature among the proposals of the method, this study analysed the influence of the internal convective heat transfer coefficient (ICHTC). In total, 25 correlations of temperature differences (temperature of the wall and internal air temperature) were analysed, as well as 20 correlations of dimensionless numbers. To do this, an experimental campaign was performed in 3 facades belonging to the most representative building periods of the building stock in Spain. First, a cluster analysis was carried out to determine similarities among the equations analysed, using the Ward method as an agglomerative hierarchical method and the Euclidean distance as an association measurement. In total, 12 and 8 groups were obtained for correlations of temperature difference and of dimensionless numbers, respectively. Afterwards, results associated with each approach were obtained. These results showed that a better adjustment was obtained for correlations of dimensionless numbers by using the approach of convection and radiation, with an average value of representative results higher than 80%. |
WOS研究方向 | Construction & Building Technology ; Engineering |
来源期刊 | BUILDING AND ENVIRONMENT
![]() |
文献类型 | 期刊论文 |
条目标识符 | http://gcip.llas.ac.cn/handle/2XKMVOVA/92983 |
作者单位 | 1.Univ Seville, Dept Graph Express & Bldg Engn, Ave Reina Mercedes 4A, E-41012 Seville, Spain; 2.Univ Cadiz, Dept Thermal Machines & Motors, Ave Republ Arabe Saharaui S-N, Puerto Real 11519, Spain |
推荐引用方式 GB/T 7714 | Bienvenido-Huertas, David,Bermudez, Javier,Moyano, Juan J.,et al. Influence of ICHTC correlations on the thermal characterization of facades using the quantitative internal infrared thermography method[J],2019,149:512-525. |
APA | Bienvenido-Huertas, David,Bermudez, Javier,Moyano, Juan J.,&Marin, David.(2019).Influence of ICHTC correlations on the thermal characterization of facades using the quantitative internal infrared thermography method.BUILDING AND ENVIRONMENT,149,512-525. |
MLA | Bienvenido-Huertas, David,et al."Influence of ICHTC correlations on the thermal characterization of facades using the quantitative internal infrared thermography method".BUILDING AND ENVIRONMENT 149(2019):512-525. |