Use of passive ground cooling for the conditioning of warehouses. | |
Gratzl, Markus1; Zieser, Johannes2; Retter, Philipp3 | |
发表日期 | 2019 |
ISSN | 0171-5445 |
EISSN | 1437-0980 |
卷号 | 41期号:1页码:60-66 |
英文摘要 | Application in modern sparkling wine production: A new production facility for a beverage manufacturer has to provide a storage volume for around 5 million bottles as a refrigerated warehouse. The maximum temperatures were not allowed to exceed 14 degrees C due to the quality requirements in the production process. To achieve highest energy efficiency and to avoid year-round heating and cooling, the warehouse should be passively conditioned: by explicitly coupling it with adjacent soil, its buffering effect was activated via uninsulated wall and floor components in contact with the ground. The warehouse stock was also integrated into the concept as thermal mass. Furthermore, the remaining building envelope was optimized to reduce heat gains and losses to external air to a minimum. The serviceability was demonstrated with a coupled thermal building simulation. It was shown that even with higher outdoor air and ground temperatures due to climate change, an active conditioning of the warehouse can be avoided when designing exterior walls and roofs of highest thermal quality. |
WOS研究方向 | Construction & Building Technology |
来源期刊 | BAUPHYSIK |
文献类型 | 期刊论文 |
条目标识符 | http://gcip.llas.ac.cn/handle/2XKMVOVA/92530 |
作者单位 | 1.Ingn Buro Gratzl eU, Reischau 5, A-4715 Taufkirchen Tr, Austria; 2.Architekt Zieser Ziviltech GmbH, Marc Aurel Str 3, A-1010 Vienna, Austria; 3.Retter & Partner Ziviltech GesmbH, Kremstalstr 49, A-3500 Krems D, Austria |
推荐引用方式 GB/T 7714 | Gratzl, Markus,Zieser, Johannes,Retter, Philipp. Use of passive ground cooling for the conditioning of warehouses.[J],2019,41(1):60-66. |
APA | Gratzl, Markus,Zieser, Johannes,&Retter, Philipp.(2019).Use of passive ground cooling for the conditioning of warehouses..BAUPHYSIK,41(1),60-66. |