CCPortal
DOI10.3964/j.issn.1000-0593(2019)01-0292-05
High Sensitivity Detection of Carbon Dioxide Based on Portable Cylindrical Multi-Pass Cell
Chen Jia-jin1,2; Wang Gui-shi1; Liu Kun1; Tan Tu1; Cheng Gang1; Tian Xing1; Gao Xiao-ming1,2
发表日期2019
ISSN1000-0593
卷号39期号:1页码:292-296
英文摘要

Carbon dioxide is one of the most important greenhouse gases playing an important role in climate change and human activities, so the detection of carbon dioxide concentration has an important significance. Highly sensitive detection of carbon dioxide gas was achieved by using near infrared tunable diode laser absorption spectroscopy combined with self-designed portable miniaturized cylindrical mirror multi-pass absorption cell. The cylindrical mirrors multi-pass absorption cell was optimized and designed by using a light transmission matrix programmed with Matlab software, compared with traditional Herriott multipass cell, which has the advantages of high mirror utilization and longer optical path length in the same volume. An effective optical path length of 14 m was achieved with 15 cm physical length. In present work, a DFB diode laser emission at 1. 57 mu m was used as a light source. Direct absorption spectroscopy method was used to detect the CO2, and the Allan variance was used to analyze the system performance. The results showed that the detection sensitivity of the system can be achieved 5. 3 mu L.L-1 with the average time of 5 s, and a detection sensitivity of 33. 1 mu L.L-1 can be achieved by averaging in 235 s. In addition, CO2 in the atmosphere was measured by the developed CO2 sensor, the measured results showed that the concentration of CO2 in the atmosphere is about 383. 4 mu L.L-1 The tunable diode laser absorption spectroscopy (IDLAS) system based on cylindrical mirrors multi-pass absorption cell, combined with the cylindrical mirrors multi pass cell can achieve long optical path in a small volume and tunable diode laser absorption spectroscopy technology has the advantages of high sensitivity, high resolution and fast response, greatly reduces volume and improves detection sensitivity of the system, which has a broad application in the field of gas detection.


WOS研究方向Spectroscopy
来源期刊SPECTROSCOPY AND SPECTRAL ANALYSIS
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/91441
作者单位1.Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Hefei 230031, Anhui, Peoples R China;
2.Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China
推荐引用方式
GB/T 7714
Chen Jia-jin,Wang Gui-shi,Liu Kun,et al. High Sensitivity Detection of Carbon Dioxide Based on Portable Cylindrical Multi-Pass Cell[J],2019,39(1):292-296.
APA Chen Jia-jin.,Wang Gui-shi.,Liu Kun.,Tan Tu.,Cheng Gang.,...&Gao Xiao-ming.(2019).High Sensitivity Detection of Carbon Dioxide Based on Portable Cylindrical Multi-Pass Cell.SPECTROSCOPY AND SPECTRAL ANALYSIS,39(1),292-296.
MLA Chen Jia-jin,et al."High Sensitivity Detection of Carbon Dioxide Based on Portable Cylindrical Multi-Pass Cell".SPECTROSCOPY AND SPECTRAL ANALYSIS 39.1(2019):292-296.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Chen Jia-jin]的文章
[Wang Gui-shi]的文章
[Liu Kun]的文章
百度学术
百度学术中相似的文章
[Chen Jia-jin]的文章
[Wang Gui-shi]的文章
[Liu Kun]的文章
必应学术
必应学术中相似的文章
[Chen Jia-jin]的文章
[Wang Gui-shi]的文章
[Liu Kun]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。