Climate Change Data Portal
DOI | 10.5740/jaoacint.13-319 |
Speciation and Preservation of Cr-VI and Cr-III in Finished Drinking Water Matrixes Using Collision Cell Ion Chromatography-Inductively Coupled Plasma-Mass Spectrometry | |
Wilson, Robert A.; Creed, Patricia A.; Pinyayev, Tatyana; Wymer, Larry; Creed, John T. | |
发表日期 | 2014-05-01 |
ISSN | 1060-3271 |
卷号 | 97期号:3页码:956-962 |
英文摘要 | The polyatomic background at the major isotope of Cr was evaluated as a function of collision cell gas flow rate using three different mobile phases. The stability of Cr-VI was evaluated as a function of solution pH by fortifying samples with enriched Cr-53(VI). The Cr-53(VI) recovery was >= 95% at pH 7.8, but by pH 6.2 a significant amount of the enriched spike was recovered as Cr-53(III)-EDTA. The instability of Cr-III at pHs above 7.8 required that Cr-III be chelated prior to speciation. The concentration of EDTA was optimized by evaluating Cr-III recoveries in six finished drinking waters, a U.S. Geological Survey reference water, and a challenge water fortified with competing matrix cations. If the Cr-III was allowed to precipitate (characteristic of shipping a sample without field preservation), acceptable recoveries of Cr-III required the sample to be heated to 70 degrees C in 10 mM EDTA to quantitatively produce the Cr-III-EDTA complex. The overall preservation/speciation approach was evaluated using an enriched Cr-53(IV) and natural Cr-III in seven drinking water matrixes over a 46 day period. A linear least squares analysis was performed on each water, and the corresponding P-values were estimated. The method detection limits for Cr-III-EDTA and Cr-VI were 0.06 and 0.1 mu g/L, respectively. |
语种 | 英语 |
WOS记录号 | WOS:000337216200042 |
来源期刊 | JOURNAL OF AOAC INTERNATIONAL
![]() |
来源机构 | 美国环保署 |
文献类型 | 期刊论文 |
条目标识符 | http://gcip.llas.ac.cn/handle/2XKMVOVA/62397 |
作者单位 | US EPA, Natl Exposure Res Lab, Cincinnati, OH 45268 USA |
推荐引用方式 GB/T 7714 | Wilson, Robert A.,Creed, Patricia A.,Pinyayev, Tatyana,et al. Speciation and Preservation of Cr-VI and Cr-III in Finished Drinking Water Matrixes Using Collision Cell Ion Chromatography-Inductively Coupled Plasma-Mass Spectrometry[J]. 美国环保署,2014,97(3):956-962. |
APA | Wilson, Robert A.,Creed, Patricia A.,Pinyayev, Tatyana,Wymer, Larry,&Creed, John T..(2014).Speciation and Preservation of Cr-VI and Cr-III in Finished Drinking Water Matrixes Using Collision Cell Ion Chromatography-Inductively Coupled Plasma-Mass Spectrometry.JOURNAL OF AOAC INTERNATIONAL,97(3),956-962. |
MLA | Wilson, Robert A.,et al."Speciation and Preservation of Cr-VI and Cr-III in Finished Drinking Water Matrixes Using Collision Cell Ion Chromatography-Inductively Coupled Plasma-Mass Spectrometry".JOURNAL OF AOAC INTERNATIONAL 97.3(2014):956-962. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。