CCPortal
DOI10.5740/jaoacint.13-319
Speciation and Preservation of Cr-VI and Cr-III in Finished Drinking Water Matrixes Using Collision Cell Ion Chromatography-Inductively Coupled Plasma-Mass Spectrometry
Wilson, Robert A.; Creed, Patricia A.; Pinyayev, Tatyana; Wymer, Larry; Creed, John T.
发表日期2014-05-01
ISSN1060-3271
卷号97期号:3页码:956-962
英文摘要

The polyatomic background at the major isotope of Cr was evaluated as a function of collision cell gas flow rate using three different mobile phases. The stability of Cr-VI was evaluated as a function of solution pH by fortifying samples with enriched Cr-53(VI). The Cr-53(VI) recovery was >= 95% at pH 7.8, but by pH 6.2 a significant amount of the enriched spike was recovered as Cr-53(III)-EDTA. The instability of Cr-III at pHs above 7.8 required that Cr-III be chelated prior to speciation. The concentration of EDTA was optimized by evaluating Cr-III recoveries in six finished drinking waters, a U.S. Geological Survey reference water, and a challenge water fortified with competing matrix cations. If the Cr-III was allowed to precipitate (characteristic of shipping a sample without field preservation), acceptable recoveries of Cr-III required the sample to be heated to 70 degrees C in 10 mM EDTA to quantitatively produce the Cr-III-EDTA complex. The overall preservation/speciation approach was evaluated using an enriched Cr-53(IV) and natural Cr-III in seven drinking water matrixes over a 46 day period. A linear least squares analysis was performed on each water, and the corresponding P-values were estimated. The method detection limits for Cr-III-EDTA and Cr-VI were 0.06 and 0.1 mu g/L, respectively.


语种英语
WOS记录号WOS:000337216200042
来源期刊JOURNAL OF AOAC INTERNATIONAL
来源机构美国环保署
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/62397
作者单位US EPA, Natl Exposure Res Lab, Cincinnati, OH 45268 USA
推荐引用方式
GB/T 7714
Wilson, Robert A.,Creed, Patricia A.,Pinyayev, Tatyana,et al. Speciation and Preservation of Cr-VI and Cr-III in Finished Drinking Water Matrixes Using Collision Cell Ion Chromatography-Inductively Coupled Plasma-Mass Spectrometry[J]. 美国环保署,2014,97(3):956-962.
APA Wilson, Robert A.,Creed, Patricia A.,Pinyayev, Tatyana,Wymer, Larry,&Creed, John T..(2014).Speciation and Preservation of Cr-VI and Cr-III in Finished Drinking Water Matrixes Using Collision Cell Ion Chromatography-Inductively Coupled Plasma-Mass Spectrometry.JOURNAL OF AOAC INTERNATIONAL,97(3),956-962.
MLA Wilson, Robert A.,et al."Speciation and Preservation of Cr-VI and Cr-III in Finished Drinking Water Matrixes Using Collision Cell Ion Chromatography-Inductively Coupled Plasma-Mass Spectrometry".JOURNAL OF AOAC INTERNATIONAL 97.3(2014):956-962.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Wilson, Robert A.]的文章
[Creed, Patricia A.]的文章
[Pinyayev, Tatyana]的文章
百度学术
百度学术中相似的文章
[Wilson, Robert A.]的文章
[Creed, Patricia A.]的文章
[Pinyayev, Tatyana]的文章
必应学术
必应学术中相似的文章
[Wilson, Robert A.]的文章
[Creed, Patricia A.]的文章
[Pinyayev, Tatyana]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。