Quantitative passive soil vapor sampling for VOCs - part 4: flow-through cell
McAlary, Todd1; Groenevelt, Hester1; Seethapathy, Suresh2; Sacco, Paolo3; Crump, Derrick4; Tuday, Michael5; Schumacher, Brian6; Hayes, Heidi7; Johnson, Paul8; Parker, Louise; Gorecki, Tadeusz2
发表日期2014
ISSN2050-7887
卷号16期号:5页码:1103-1111
英文摘要

This paper presents a controlled experiment comparing several quantitative passive samplers for monitoring concentrations of volatile organic compound (VOC) vapors in soil gas using a flow-through cell. This application is simpler than conventional active sampling using adsorptive tubes because the flow rate does not need to be precisely measured and controlled, which is advantageous because the permeability of subsurface materials affects the flow rate and the permeability of geologic materials is highly variable. Using passive samplers in a flow-through cell, the flow rate may not need to be known exactly, as long as it is sufficient to purge the cell in a reasonable time and minimize any negative bias attributable to the starvation effect. An experiment was performed in a 500 mL flow-through cell using a two-factor, one-half fraction fractional factorial test design with flow rates of 80, 670 and 930 mL min(-1) and sample durations of 10, 15 and 20 minutes for each of five different passive samplers (passive Automatic Thermal Desorption Tube, Radiello (R), SKC Ultra, Waterloo Membrane Sampler (TM) and 3M (TM) OVM 3500). A Summa canister was collected coincident with each passive sampler and analyzed by EPA Method TO-15 to provide a baseline for comparison of the passive sampler concentrations. The passive sampler concentrations were within a factor of 2 of the Summa canister concentrations in 32 of 35 cases. Passive samples collected at the low flow rate and short duration showed low concentrations, which is likely attributable to insufficient purging of the cell after sampler placement.


语种英语
WOS记录号WOS:000335003900018
来源期刊ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS
来源机构美国环保署
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/61400
作者单位1.Geosyntec Consultants Inc, Guelph, ON N1G 5G3, Canada;
2.Univ Waterloo, Waterloo, ON N2L 3G1, Canada;
3.Fdn Salvatore Maugeri, Padua, Italy;
4.Cranfield Univ, Cranfield MK43 0AL, Beds, England;
5.Columbia Analyt Serv, Simi Valley, CA USA;
6.US EPA, Las Vegas, NV USA;
7.Eurofins Air Toxics Inc, Folsom, CA USA;
8.Arizona State Univ, Tempe, AZ USA
推荐引用方式
GB/T 7714
McAlary, Todd,Groenevelt, Hester,Seethapathy, Suresh,et al. Quantitative passive soil vapor sampling for VOCs - part 4: flow-through cell[J]. 美国环保署,2014,16(5):1103-1111.
APA McAlary, Todd.,Groenevelt, Hester.,Seethapathy, Suresh.,Sacco, Paolo.,Crump, Derrick.,...&Gorecki, Tadeusz.(2014).Quantitative passive soil vapor sampling for VOCs - part 4: flow-through cell.ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS,16(5),1103-1111.
MLA McAlary, Todd,et al."Quantitative passive soil vapor sampling for VOCs - part 4: flow-through cell".ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS 16.5(2014):1103-1111.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[McAlary, Todd]的文章
[Groenevelt, Hester]的文章
[Seethapathy, Suresh]的文章
百度学术
百度学术中相似的文章
[McAlary, Todd]的文章
[Groenevelt, Hester]的文章
[Seethapathy, Suresh]的文章
必应学术
必应学术中相似的文章
[McAlary, Todd]的文章
[Groenevelt, Hester]的文章
[Seethapathy, Suresh]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。