CCPortal
DOI10.5194/amt-11-4823-2018
Field evaluation of low-cost particulate matter sensors in high-and low-concentration environments
Zheng, Tongshu1; Bergin, Michael H.1; Johnson, Karoline K.1; Tripathi, Sachchida N.2; Shirodkar, Shilpa2; Landis, Matthew S.3; Sutaria, Ronak4; Carlson, David E.1,5
发表日期2018-08-22
ISSN1867-1381
卷号11期号:8页码:4823-4846
英文摘要

Low-cost particulate matter (PM) sensors are promising tools for supplementing existing air quality monitoring networks. However, the performance of the new generation of low-cost PM sensors under field conditions is not well understood. In this study, we characterized the performance capabilities of a new low-cost PM sensor model (Plan-tower model PMS3003) for measuring PM2.5 at 1 min, 1 h, 6 h, 12 h, and 24 h integration times. We tested the PMS3003 sensors in both low-concentration suburban regions (Durham and Research Triangle Park (RTP), NC, US) with 1 h PM2.5 (mean +/- SD) of 9 +/- 9 and 10 +/- 3 mu g m(-3), respectively, and a high-concentration urban location (Kanpur, India) with 1 h PM2.5 of 36 +/- 17 and 116 +/- 57 mu g m(-3) during monsoon and post-monsoon seasons, respectively. In Durham and Kanpur, the sensors were compared to a research-grade instrument (environmental beta attenuation monitor, E-BAM) to determine how these sensors perform across a range of PM2.5 concentrations and meteorological factors (e.g., temperature and relative humidity, RH). In RTP, the sensors were compared to three Federal Equivalent Methods (FEMs) including two Teledyne model T640s and a Thermo Scientific model 5030 SHARP to demonstrate the importance of the type of reference monitor selected for sensor calibration. The decrease in 1 h mean errors of the calibrated sensors using univariate linear models from Durham (201 %) to Kanpur monsoon (46 %) and post-monsoon (35 %) seasons showed that PMS3003 performance generally improved as ambient PM2.5 increased. The precision of reference instruments (T640: +/- 0.5 mu g m(-3) for 1 h; SHARP: +/- 2 mu g m(-3) for 24 h, better than the E-BAM) is critical in evaluating sensor performance, and beta-attenuation-based monitors may not be ideal for testing PM sensors at low concentrations, as underscored by (1) the less dramatic error reduction over averaging times in RTP against optically based T640 (from 27% for 1 h to 9% for 24 h) than in Durham (from 201% to 15 %); (2) the lower errors in RTP than the Kanpur post-monsoon season (from 35% to 11 %); and (3) the higher T640-PMS3003 correlations (R-2 >= 0.63) than SHARP-PMS3003 (R-2 >= 0.25). A major RH influence was found in RTP (1 h RH = 64 +/- 22 %) due to the relatively high precision of the T640 measurements that can explain up to similar to 30% of the variance in 1 min to 6 h PMS3003 PM2.5 measurements. When proper RH corrections are made by empirical nonlinear equations after using a more precise reference method to calibrate the sensors, our work suggests that the PMS3003 sensors can measure PM2.5 concentrations within similar to 10% of ambient values. We observed that PMS3003 sensors appeared to exhibit a nonlinear response when ambient PM2.5 exceeded similar to 125 mu g m(-3) and found that the quadratic fit is more appropriate than the univariate linear model to capture this nonlinearity and can further reduce errors by up to 11 %. Our results have substantial implications for how variability in ambient PM2.5 concentrations, reference monitor types, and meteorological factors can affect PMS3003 performance characterization.


语种英语
WOS记录号WOS:000442398300001
来源期刊ATMOSPHERIC MEASUREMENT TECHNIQUES
来源机构美国环保署
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/60445
作者单位1.Duke Univ, Dept Civil & Environm Engn, Durham, NC 27708 USA;
2.Indian Inst Technol Kanpur, Dept Civil Engn, Kanpur 208016, Uttar Pradesh, India;
3.US EPA, Off Res & Dev, Res Triangle Pk, NC 27711 USA;
4.Indian Inst Technol, Ctr Urban Sci & Engn, Bombay 400076, Maharashtra, India;
5.Duke Univ, Dept Biostat & Bioinformat, Durham, NC 27708 USA
推荐引用方式
GB/T 7714
Zheng, Tongshu,Bergin, Michael H.,Johnson, Karoline K.,et al. Field evaluation of low-cost particulate matter sensors in high-and low-concentration environments[J]. 美国环保署,2018,11(8):4823-4846.
APA Zheng, Tongshu.,Bergin, Michael H..,Johnson, Karoline K..,Tripathi, Sachchida N..,Shirodkar, Shilpa.,...&Carlson, David E..(2018).Field evaluation of low-cost particulate matter sensors in high-and low-concentration environments.ATMOSPHERIC MEASUREMENT TECHNIQUES,11(8),4823-4846.
MLA Zheng, Tongshu,et al."Field evaluation of low-cost particulate matter sensors in high-and low-concentration environments".ATMOSPHERIC MEASUREMENT TECHNIQUES 11.8(2018):4823-4846.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zheng, Tongshu]的文章
[Bergin, Michael H.]的文章
[Johnson, Karoline K.]的文章
百度学术
百度学术中相似的文章
[Zheng, Tongshu]的文章
[Bergin, Michael H.]的文章
[Johnson, Karoline K.]的文章
必应学术
必应学术中相似的文章
[Zheng, Tongshu]的文章
[Bergin, Michael H.]的文章
[Johnson, Karoline K.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。