CCPortal
DOI10.1007/s10661-015-4595-2
Field monitoring of a LID-BMP treatment train system in China
Jia, Haifeng1; Wang, Xiangwen1; Ti, Chaopu1; Zhai, Yanyun2; Field, Richard3; Tafuri, Anthony N.3; Cai, Huihua4; Yu, Shaw L.5
发表日期2015-06-01
ISSN0167-6369
卷号187期号:6
英文摘要

In order to assess the urban runoff control effectiveness of a low-impact development best management practice (LID-BMP) treatment train system, a field test of selected LID-BMPs was conducted in China. The LID-BMPs selected include three grassed swales, a buffer strip, a bioretention cell, two infiltration pits, and a constructed wetland. The test site is in a campus in southern China. The LID-BMPs, connected in a series, received stormwater runoff from four tennis courts with an area of 2808 m(2) and eight basketball courts with an area of 4864 m(2). Construction of the LID-BMPs was completed in early spring of 2012, and the sampling was conducted during May of 2012 to September of 2013. During the sampling effort, besides the performance evaluations of grassed swales and the bioretention cell in controlling runoff quantity as well as quality, the emphasis was also on determining the performance of the LID-BMP treatment train system. A total of 19 storm events were monitored, with nine producing no runoff and ten producing runoff. Data collected from the ten storm events were analyzed for estimating runoff quantity (peak flow rate and total runoff volume) and quality reduction by the LID-BMPs. The sum of loads (SOL) method was used for calculating the water quality performance of LID-BMPs. Results indicated that, for peak flow rate, a bioretention cell reduction of 50-84 % was obtained, and grassed swale reduction was 17-79 %, with a runoff volume reduction of 47-80 and 9-74 %, respectively. For water quality, the bioretention cell in general showed good removal for zinc (nearly 100 %), copper (69 %), NH3-N (ammonia nitrogen) (51 %), and total nitrogen (TN) (49 %); fair removal for chemical oxygen demand (COD) (18 %); and poor removal for total suspended solids (TSS) (-11 %) and total phosphorus (TP) (-21 %). And its performance effectiveness for pollutant removal increased in the second year after 1 year of stabilizing. When considering the aggregated effect of the LIDBMP treatment train system, it showed excellent removal for NH3-N (73%), TN (74%), and TP (95 %) and fair removal for COD (19 %) and TSS (35 %). The assessment results of the LID-BMP treatment train system provide valuable information on how to link the different types of LID-BMP facilities and maximize the integrated effectiveness on urban runoff control.


英文关键词LID-BMP treatment train;Grassed swales;Bioretention;Field test;Green campus;Southern China
语种英语
WOS记录号WOS:000355918600018
来源期刊ENVIRONMENTAL MONITORING AND ASSESSMENT
来源机构美国环保署
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/59975
作者单位1.Tsinghua Univ, Sch Environm, Beijing 100084, Peoples R China;
2.Ecovista Environm Consulting Inc, Shenzhen, Guangdong, Peoples R China;
3.US EPA, Watershed Management Branch, Natl Risk Management Res Lab, Edison, NJ USA;
4.Guangdong Vocat Coll Environm Protect Engn, Foshan, Guangdong, Peoples R China;
5.Univ Virginia, Dept Civil & Environm Engn, Charlottesville, VA USA
推荐引用方式
GB/T 7714
Jia, Haifeng,Wang, Xiangwen,Ti, Chaopu,et al. Field monitoring of a LID-BMP treatment train system in China[J]. 美国环保署,2015,187(6).
APA Jia, Haifeng.,Wang, Xiangwen.,Ti, Chaopu.,Zhai, Yanyun.,Field, Richard.,...&Yu, Shaw L..(2015).Field monitoring of a LID-BMP treatment train system in China.ENVIRONMENTAL MONITORING AND ASSESSMENT,187(6).
MLA Jia, Haifeng,et al."Field monitoring of a LID-BMP treatment train system in China".ENVIRONMENTAL MONITORING AND ASSESSMENT 187.6(2015).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Jia, Haifeng]的文章
[Wang, Xiangwen]的文章
[Ti, Chaopu]的文章
百度学术
百度学术中相似的文章
[Jia, Haifeng]的文章
[Wang, Xiangwen]的文章
[Ti, Chaopu]的文章
必应学术
必应学术中相似的文章
[Jia, Haifeng]的文章
[Wang, Xiangwen]的文章
[Ti, Chaopu]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。