CCPortal
DOI10.4209/aaqr.2017.10.0418
Field Test of Several Low-Cost Particulate Matter Sensors in High and Low Concentration Urban Environments
Johnson, Karoline K.1; Bergin, Michael H.1; Russell, Armistead G.2; Hagler, Gayle S. W.3
发表日期2018-03-01
ISSN1680-8584
卷号18期号:3页码:565-578
英文摘要

Detailed quantification of the spatial and temporal variability of ambient fine particulate matter (PM2.5) has, to date, been limited due to the cost and logistics involved with traditional monitoring approaches. New miniaturized particle sensors are a potential strategy to gather more time-and spatially-resolved data, to address data gaps in regions with limited monitoring and to address important air quality research priorities in a more cost-effective manner. This work presents field evaluations and lab testing of three models of low-cost (< $200) PM sensors (SHINYEI: models PPD42NS, PPD20V, PPD60PV) in three locations: urban background (average PM2.5: 8 mu g m(-3)) and roadside in Atlanta, Georgia, USA (average PM2.5: 21 mu g m(-3)), and a location with higher ambient concentrations in Hyderabad, India (average PM2.5: 72 mu g m(-3)). Sensor measurements were compared against reference monitors in the lab using one-minute averages and in field locations using one-hour averages. At the Atlanta sites the sensors were weakly correlated with a tapered element oscillating microbalance (TEOM) at best (R-2 <= 0.30). In Hyderabad, the PPD20V sensors had the highest correlation with the environmental beta attenuation monitor (E-BAM) (R-2 > 0.80), however the same sensors had poor agreement if the comparison was restricted to lower concentrations (R-2 = similar to 0, < 40 mu g m(-3)). The results of this work indicate the potential usefulness of these sensors, including the PPD20V, for higher concentration applications (< similar to 250 mu g m(-3)). These field-testing results provide important insights into the varying performance of low-cost PM sensors under highly contrasting atmospheric conditions. The inconsistent performance results underscore the need for rigorous evaluation of optical particle sensors in the laboratory and in diverse field environments.


英文关键词Field calibration;Fine particulate matter;SHINYEI;Low-cost sensor
语种英语
WOS记录号WOS:000427410500001
来源期刊AEROSOL AND AIR QUALITY RESEARCH
来源机构美国环保署
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/59795
作者单位1.Duke Univ, Sch Civil & Environm Engn, Durham, NC 27708 USA;
2.Georgia Inst Technol, Sch Civil & Environm Engn, Atlanta, GA 30332 USA;
3.US EPA, Off Res & Dev, Res Triangle Pk, NC 27711 USA
推荐引用方式
GB/T 7714
Johnson, Karoline K.,Bergin, Michael H.,Russell, Armistead G.,et al. Field Test of Several Low-Cost Particulate Matter Sensors in High and Low Concentration Urban Environments[J]. 美国环保署,2018,18(3):565-578.
APA Johnson, Karoline K.,Bergin, Michael H.,Russell, Armistead G.,&Hagler, Gayle S. W..(2018).Field Test of Several Low-Cost Particulate Matter Sensors in High and Low Concentration Urban Environments.AEROSOL AND AIR QUALITY RESEARCH,18(3),565-578.
MLA Johnson, Karoline K.,et al."Field Test of Several Low-Cost Particulate Matter Sensors in High and Low Concentration Urban Environments".AEROSOL AND AIR QUALITY RESEARCH 18.3(2018):565-578.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Johnson, Karoline K.]的文章
[Bergin, Michael H.]的文章
[Russell, Armistead G.]的文章
百度学术
百度学术中相似的文章
[Johnson, Karoline K.]的文章
[Bergin, Michael H.]的文章
[Russell, Armistead G.]的文章
必应学术
必应学术中相似的文章
[Johnson, Karoline K.]的文章
[Bergin, Michael H.]的文章
[Russell, Armistead G.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。