Climate Change Data Portal
DOI | 10.1016/j.chroma.2017.07.082 |
Calibration and performance of synchronous SIM/scan mode for simultaneous targeted and discovery (non-targeted) analysis of exhaled breath samples from firefighters | |
Wallace, M. Ariel Geer1; Pleil, Joachim D.1; Mentese, Sibel2; Oliver, Karen D.1; Whitaker, Donald A.1; Fent, Kenneth W.3 | |
发表日期 | 2017-09-22 |
ISSN | 0021-9673 |
卷号 | 1516页码:114-124 |
英文摘要 | Traditionally, gas chromatography-mass spectrometry (GC/MS) analysis has used a targeted approach called selected ion monitoring (SIM) to quantify specific compounds that may have adverse health effects. Dueto method limitations and the constraints of preparing duplicate samples, the information that could be obtained from separately collecting the full scan chromatogram of the sample has often been sacrificed. However, the hybrid technique called synchronous SIM/scan mode alternates between the two acquisition modes, maintaining the accuracy and sensitivity of SIM for targeted analysis while also providing the full scan chromatogram for discovery of non-target compounds. This technology was assessed using calibration data and real-world breath samples from a joint EPA/NIOSH collaboration that investigated the safety of firefighters' protective gear during controlled structure burns. Collecting field samples is costly and must be performed strategically to ensure that time points and replicates are accurate and representative of the intended population. This is difficult to accomplish with firefighters who are working under volatile conditions. The synchronous SIM/scan method decreases the number of field samples that need to be collected by half and reduces error in trying to recreate time points since a breath sample from a single sorbent tube can be used to collect both the SIM and scan data simultaneously. As a practical demonstration of the method, we investigate thirty-six firefighter breath samples, document organic compounds of interest, and identify additional non-target compounds. Published by Elsevier B.V. |
英文关键词 | Selected ion monitoring/scan (SIM/scan);Gas chromatography-mass spectrometry (GC/MS);Automated thermal desorption (ATD);Volatile organic compound (VOC);Polyaromatic hydrocarbon (PAH);Breath research |
语种 | 英语 |
WOS记录号 | WOS:000411542600012 |
来源期刊 | JOURNAL OF CHROMATOGRAPHY A |
来源机构 | 美国环保署 |
文献类型 | 期刊论文 |
条目标识符 | http://gcip.llas.ac.cn/handle/2XKMVOVA/59642 |
作者单位 | 1.US EPA, Off Res & Dev, Natl Exposure Res Lab, Res Triangle Pk, NC 27711 USA; 2.Canakkale Onsekiz Mart Univ, Dept Environm Engn, Merkez, Canakkale, Turkey; 3.NIOSH, Div Surveillance Hazard Evaluat & Field Studies, Cincinnati, OH 45226 USA |
推荐引用方式 GB/T 7714 | Wallace, M. Ariel Geer,Pleil, Joachim D.,Mentese, Sibel,et al. Calibration and performance of synchronous SIM/scan mode for simultaneous targeted and discovery (non-targeted) analysis of exhaled breath samples from firefighters[J]. 美国环保署,2017,1516:114-124. |
APA | Wallace, M. Ariel Geer,Pleil, Joachim D.,Mentese, Sibel,Oliver, Karen D.,Whitaker, Donald A.,&Fent, Kenneth W..(2017).Calibration and performance of synchronous SIM/scan mode for simultaneous targeted and discovery (non-targeted) analysis of exhaled breath samples from firefighters.JOURNAL OF CHROMATOGRAPHY A,1516,114-124. |
MLA | Wallace, M. Ariel Geer,et al."Calibration and performance of synchronous SIM/scan mode for simultaneous targeted and discovery (non-targeted) analysis of exhaled breath samples from firefighters".JOURNAL OF CHROMATOGRAPHY A 1516(2017):114-124. |
条目包含的文件 | 条目无相关文件。 |