Climate Change Data Portal
DOI | 10.1186/s12989-014-0054-4 |
Ozone co-exposure modifies cardiac responses to fine and ultrafine ambient particulate matter in mice: concordance of electrocardiogram and mechanical responses | |
Kurhanewicz, Nicole1; McIntosh-Kastrinsky, Rachel2; Tong, Haiyan3; Walsh, Leon3; Farraj, Aimen K.3; Hazari, Mehdi S.3 | |
发表日期 | 2014-10-16 |
ISSN | 1743-8977 |
卷号 | 11 |
英文摘要 | Background: Studies have shown a relationship between air pollution and increased risk of cardiovascular morbidity and mortality. Due to the complexity of ambient air pollution composition, recent studies have examined the effects of co-exposure, particularly particulate matter (PM) and gas, to determine whether pollutant interactions alter (e.g. synergistically, antagonistically) the health response. This study examines the independent effects of fine (FCAPs) and ultrafine (UFCAPs) concentrated ambient particles on cardiac function, and determine the impact of ozone (O-3) co-exposure on the response. We hypothesized that UFCAPs would cause greater decrement in mechanical function and electrical dysfunction than FCAPs, and that O-3 co-exposure would enhance the effects of both particle-types. Methods: Conscious/unrestrained radiotelemetered mice were exposed once whole-body to either 190 mu g/m(3) FCAPs or 140 mu g/m(3) UFCAPs with/without 0.3 ppm O-3; separate groups were exposed to either filtered air (FA) or O-3 alone. Heart rate (HR) and electrocardiogram (ECG) were recorded continuously before, during and after exposure, and cardiac mechanical function was assessed using a Langendorff perfusion preparation 24 hrs post-exposure. Results: FCAPs alone caused a significant decrease in baseline left ventricular developed pressure (LVDP) and contractility, whereas UFCAPs did not; neither FCAPs nor UFCAPs alone caused any ECG changes. O-3 co-exposure with FCAPs caused a significant decrease in heart rate variability when compared to FA but also blocked the decrement in cardiac function. On the other hand, O-3 co-exposure with UFCAPs significantly increased QRS-interval, QTc and non-conducted P-wave arrhythmias, and decreased LVDP, rate of contractility and relaxation when compared to controls. Conclusions: These data suggest that particle size and gaseous interactions may play a role in cardiac function decrements one day after exposure. Although FCAPs + O-3 only altered autonomic balance, UFCAPs + O-3 appeared to be more serious by increasing cardiac arrhythmias and causing mechanical decrements. As such, O-3 appears to interact differently with FCAPs and UFCAPs, resulting in varied cardiac changes, which suggests that the cardiovascular effects of particle-gas co-exposures are not simply additive or even generalizable. Additionally, the mode of toxicity underlying this effect may be subtle given none of the exposures described here impaired post-ischemia recovery. |
英文关键词 | Air pollution;Cardiac function;Ventricular contraction;Electrocardiogram;Arrhythmia;Particulate matter |
语种 | 英语 |
WOS记录号 | WOS:000345872000001 |
来源期刊 | PARTICLE AND FIBRE TOXICOLOGY
![]() |
来源机构 | 美国环保署 |
文献类型 | 期刊论文 |
条目标识符 | http://gcip.llas.ac.cn/handle/2XKMVOVA/58229 |
作者单位 | 1.Univ N Carolina, Sch Med, Curriculum Toxicol, Chapel Hill, NC 27599 USA; 2.Univ N Carolina, Gillings Sch Global Publ Hlth, Dept Environm Sci & Engn, Chapel Hill, NC 27599 USA; 3.US EPA, Natl Hlth & Environm Effects Res Lab, Environm Publ Hlth Div, Chapel Hill, NC 27711 USA |
推荐引用方式 GB/T 7714 | Kurhanewicz, Nicole,McIntosh-Kastrinsky, Rachel,Tong, Haiyan,et al. Ozone co-exposure modifies cardiac responses to fine and ultrafine ambient particulate matter in mice: concordance of electrocardiogram and mechanical responses[J]. 美国环保署,2014,11. |
APA | Kurhanewicz, Nicole,McIntosh-Kastrinsky, Rachel,Tong, Haiyan,Walsh, Leon,Farraj, Aimen K.,&Hazari, Mehdi S..(2014).Ozone co-exposure modifies cardiac responses to fine and ultrafine ambient particulate matter in mice: concordance of electrocardiogram and mechanical responses.PARTICLE AND FIBRE TOXICOLOGY,11. |
MLA | Kurhanewicz, Nicole,et al."Ozone co-exposure modifies cardiac responses to fine and ultrafine ambient particulate matter in mice: concordance of electrocardiogram and mechanical responses".PARTICLE AND FIBRE TOXICOLOGY 11(2014). |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。