CCPortal
DOI10.1080/02786826.2017.1316358
Revisiting the size selective performance of EPA's high-volume total suspended particulate matter (Hi-Vol TSP) sampler
Krug, Jonathan D.1; Dart, Andrew2; Witherspoon, Carlton L.3; Gilberry, Jerome2,3; Malloy, Quentin2; Kaushik, Surender1; Vanderpool, Robert W.1
发表日期2017
ISSN0278-6826
卷号51期号:7页码:868-878
英文摘要

Under the National Ambient Air Quality Standard (NAAQS) for airborne lead, measurements are conducted by means of a high-volume total suspended particulate matter (Hi-Vol TSP) sampler. In the decade between 1973 and 1983, there were 12 publications that explored the sampling characteristics and effectiveness of the Hi-Vol TSP, yet there persists uncertainty regarding its performance. This article presents an overview of the existing literature on the performance of the Hi-Vol TSP, and identifies the reported sampler effectiveness with respect to four factors: particle size (reported effectiveness of 7%-100%), wind speed (-36% to 100%), sampler orientation (7%-100%), and operational state (107%-140%). Effectiveness of the Hi-Vol TSP was evaluated with a solid, polydisperse aerosol in a controlled wind tunnel setting. Isokinetic samplers were deployed alongside the Hi-Vol TSP to investigate three wind speeds (2, 8, and 24km h(-1)), three sampler orientations (0 degrees, 45 degrees, 90 degrees), and two operational states (on, off) for aerosols with aerodynamic diameters from 5 to 35 mu m. Results indicate that particle diameter was the largest determining factor of effectiveness followed by wind speed. Orientation of the sampler did not have a significant effect at 2 and 8km h(-1) but did at 24km h(-1). In a passive state, the Hi-Vol TSP was collected between 1% and 7% of available aerosol depending on particle size and wind speed. Results of this research do not invalidate results of previous studies but rather contribute to our overall understanding of the Hi-Vol TSP's size-selective performance. While results generally agreed with previous studies, the Hi-Vol TSP was found to exhibit less dependence on these four factors than previously reported.(c) 2017 American Association for Aerosol Research


英文关键词Kihong Park
语种英语
WOS记录号WOS:000402057000007
来源期刊AEROSOL SCIENCE AND TECHNOLOGY
来源机构美国环保署
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/58033
作者单位1.US EPA, Res Triangle Pk, NC 27711 USA;
2.RTI Int, Res Triangle Pk, NC USA;
3.Jacobs Technol Inc, Res Triangle Pk, NC USA
推荐引用方式
GB/T 7714
Krug, Jonathan D.,Dart, Andrew,Witherspoon, Carlton L.,et al. Revisiting the size selective performance of EPA's high-volume total suspended particulate matter (Hi-Vol TSP) sampler[J]. 美国环保署,2017,51(7):868-878.
APA Krug, Jonathan D..,Dart, Andrew.,Witherspoon, Carlton L..,Gilberry, Jerome.,Malloy, Quentin.,...&Vanderpool, Robert W..(2017).Revisiting the size selective performance of EPA's high-volume total suspended particulate matter (Hi-Vol TSP) sampler.AEROSOL SCIENCE AND TECHNOLOGY,51(7),868-878.
MLA Krug, Jonathan D.,et al."Revisiting the size selective performance of EPA's high-volume total suspended particulate matter (Hi-Vol TSP) sampler".AEROSOL SCIENCE AND TECHNOLOGY 51.7(2017):868-878.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Krug, Jonathan D.]的文章
[Dart, Andrew]的文章
[Witherspoon, Carlton L.]的文章
百度学术
百度学术中相似的文章
[Krug, Jonathan D.]的文章
[Dart, Andrew]的文章
[Witherspoon, Carlton L.]的文章
必应学术
必应学术中相似的文章
[Krug, Jonathan D.]的文章
[Dart, Andrew]的文章
[Witherspoon, Carlton L.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。