Using performance reference compounds to compare mass transfer calibration methodologies in passive samplers deployed in the water column | |
Joyce, Abigail S.; Burgess, Robert M. | |
发表日期 | 2018-08-01 |
ISSN | 0730-7268 |
卷号 | 37期号:8页码:2089-2097 |
英文摘要 | Performance reference compounds (PRCs) are often added to passive samplers prior to field deployments to provide information about mass transfer kinetics between the sampled environment and the passive sampler. Their popularity has resulted in different methods of varying complexity to estimate mass transfer and better estimate freely dissolved concentrations (C-free) of targeted compounds. Three methods for describing a mass transfer model are commonly used: a first-order kinetic method, a nonlinear least squares fitting of sampling rate, and a diffusion method. Low-density polyethylene strips loaded with PRCs and of 4 different thicknesses were used as passive samplers to create an array of PRC results to assess the comparability and reproducibility of each of the methods. Samplers were deployed in the water column at 3 stations in New Bedford Harbor (MA, USA). Collected data allowed C-free comparisons to be performed in 2 ways: 1) comparison of C-free derived from one thickness using different methods, and 2) comparison of C-free derived by the same method using different thicknesses of polyethylene. Overall, the nonlinear least squares and diffusion methods demonstrated the most precise results for all the PCBs measured and generated C-free values that were often statistically indistinguishable. Relative standard deviations (RSDs) for total PCB measurements using the same thickness and varying model types ranged from 0.04 to 12% and increased with sampler thickness, and RSDs for estimates using the same method and varying thickness ranged from 8 to 18%. Environmental scientists and managers are encouraged to use these methods when estimating C-free from passive sampling and PRC data. Environ Toxicol Chem 2018;37:2089-2097. Published 2018 Wiley Periodicals Inc. on behalf of SETAC. This article is a US government work and, as such, is in the public domain in the United States of America. |
英文关键词 | Passive sampling;Polychlorinated biphenyls;Persistent organic pollutants;Performance reference compounds |
语种 | 英语 |
WOS记录号 | WOS:000439771200004 |
来源期刊 | ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY
![]() |
来源机构 | 美国环保署 |
文献类型 | 期刊论文 |
条目标识符 | http://gcip.llas.ac.cn/handle/2XKMVOVA/57865 |
作者单位 | US EPA, Atlantic Ecol Div, Natl Hlth & Environm Effects Res Lab, Off Res & Dev, Narragansett, RI 02882 USA |
推荐引用方式 GB/T 7714 | Joyce, Abigail S.,Burgess, Robert M.. Using performance reference compounds to compare mass transfer calibration methodologies in passive samplers deployed in the water column[J]. 美国环保署,2018,37(8):2089-2097. |
APA | Joyce, Abigail S.,&Burgess, Robert M..(2018).Using performance reference compounds to compare mass transfer calibration methodologies in passive samplers deployed in the water column.ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY,37(8),2089-2097. |
MLA | Joyce, Abigail S.,et al."Using performance reference compounds to compare mass transfer calibration methodologies in passive samplers deployed in the water column".ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY 37.8(2018):2089-2097. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。