Decontamination of Bacillus spores adhered to iron and cement-mortar drinking water infrastructure in a model system using disinfectants | |
Szabo, Jeffrey G.1; Meiners, Greg2; Heckman, Lee2; Rice, Eugene W.1; Hall, John1 | |
发表日期 | 2017-02-01 |
ISSN | 0301-4797 |
卷号 | 187页码:1-7 |
英文摘要 | Decontamination of Bacillus spores adhered to common drinking water infrastructure surfaces was evaluated using a variety of disinfectants. Corroded iron and cement-mortar lined iron represented the infrastructure surfaces, and were conditioned in a 23 m long, 15 cm diameter (75 ft long, 6 in diameter) pilot-scale drinking water distribution pipe system. Decontamination was evaluated using increased water velocity (flushing) alone at 0.5 m s(-1) (1.7 ft s(-1)), as well as free chlorine (5 and 25 mg L-1), monochloramine (25 mg L-1), chlorine dioxide (5 and 25 mg L-1), ozone (2.0 mg L-1), peracetic acid 25 mg L-1) and acidified nitrite (0.1 mol L-1 at pH 2 and 3), all followed by flushing at 0.3 m s(-1) (1 ft s(-1)). Flushing alone reduced the adhered spores by 0.5 and 2.0 log(10) from iron and cement-mortar, respectively. Log(10) reduction on corroded iron pipe wall coupons ranged from 1.0 to 2.9 at respective chlorine dioxide concentrations of 5 and 25 mg L-1, although spores were undetectable on the iron surface during disinfection at 25 mg L-1. Acidified nitrite (pH 2, 0.1 mol L-1) yielded no detectable spores on the iron surface during the flushing phase after disinfection. Chlorine dioxide was the best performing disinfectant with >3.0 log(10) removal from cement-mortar at 5 and 25 mg L-1. The data show that free chlorine, monochloramine, ozone and chlorine dioxide followed by flushing can reduce adhered spores by > 3.0 log(10) on cement-mortar. (C) 2016 Elsevier B.V. All rights reserved. |
英文关键词 | Drinking water;Decontamination;Disinfection;Bacillus;Spores |
语种 | 英语 |
WOS记录号 | WOS:000392037500001 |
来源期刊 | JOURNAL OF ENVIRONMENTAL MANAGEMENT |
来源机构 | 美国环保署 |
文献类型 | 期刊论文 |
条目标识符 | http://gcip.llas.ac.cn/handle/2XKMVOVA/57059 |
作者单位 | 1.US EPA, Natl Homeland Secur Res Ctr, Water Infrastruct Protect Div, 26 W Martin Luther King Dr,MS NG 16, Cincinnati, OH 45268 USA; 2.CB&I Fed Serv LLC, 1600 Gest St, Cincinnati, OH 45204 USA |
推荐引用方式 GB/T 7714 | Szabo, Jeffrey G.,Meiners, Greg,Heckman, Lee,et al. Decontamination of Bacillus spores adhered to iron and cement-mortar drinking water infrastructure in a model system using disinfectants[J]. 美国环保署,2017,187:1-7. |
APA | Szabo, Jeffrey G.,Meiners, Greg,Heckman, Lee,Rice, Eugene W.,&Hall, John.(2017).Decontamination of Bacillus spores adhered to iron and cement-mortar drinking water infrastructure in a model system using disinfectants.JOURNAL OF ENVIRONMENTAL MANAGEMENT,187,1-7. |
MLA | Szabo, Jeffrey G.,et al."Decontamination of Bacillus spores adhered to iron and cement-mortar drinking water infrastructure in a model system using disinfectants".JOURNAL OF ENVIRONMENTAL MANAGEMENT 187(2017):1-7. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。