Climate Change Data Portal
DOI | 10.1021/acs.est.8b00224 |
Measurements of Parameters Controlling the Emissions of Organophosphate Flame Retardants in Indoor Environments | |
Liang, Yirui1; Liu, Xiaoyu2; Allen, Matthew R.3 | |
发表日期 | 2018-05-15 |
ISSN | 0013-936X |
卷号 | 52期号:10页码:5821-5829 |
英文摘要 | Emission of semivolatile organic compounds (SVOCs) from source materials usually occurs very slowly in indoor environments due to their low volatility. When the SVOC emission process is controlled by external mass transfer, the gas phase concentration in equilibrium with the material (y(0)) is used as a key parameter to simplify the source models that are based on solid-phase diffusion. A material-air-material (M-A-M) configured microchamber method was developed to rapidly measure y(0) for a polyisocyanurate rigid foam material containing organophosphate flame retardants (OPRFs). The emission test was conducted in 44 mL microchambers for target OPFRs, including tris(2-chloroethyl) phosphate (CASRN: 115-96-8), tris(1-chloro-2-propyl) phosphate (CASRN: 13674-84-5), and tris(1,3-dichloro-2-propyl) phosphate (CASRN: 13674-87-8). In addition to the microchamber emission test, two other types of tests were conducted to determine y(0) for the same foam material: OPFR diffusive tube sampling tests from the OPFR source foam using stainless-steel thermal desorption tubes and sorption tests of OPFR on an OPFR-free foam in a 53 L small chamber. Comparison of parameters obtained from the three methods suggests that the discrepancy could be caused by a combination of theoretical, experimental, and computational differences. Based on the y(0) measurements, a linear relationship between the ratio of y(0) to saturated vapor pressure concentration and material-phase mass fractions has been found for phthalates and OPFRs. |
语种 | 英语 |
WOS记录号 | WOS:000432417400034 |
来源期刊 | ENVIRONMENTAL SCIENCE & TECHNOLOGY |
来源机构 | 美国环保署 |
文献类型 | 期刊论文 |
条目标识符 | http://gcip.llas.ac.cn/handle/2XKMVOVA/57034 |
作者单位 | 1.US EPA, Oak Ridge Inst Sci & Educ Participant, 1299 Bethel Valley Rd, Oak Ridge, TN 37830 USA; 2.US EPA, Off Res & Dev, Natl Risk Management Res Lab, Res Triangle Pk, NC 27711 USA; 3.Jacobs Technol Inc, 600 William Northern Blvd, Tullahoma, TN 37388 USA |
推荐引用方式 GB/T 7714 | Liang, Yirui,Liu, Xiaoyu,Allen, Matthew R.. Measurements of Parameters Controlling the Emissions of Organophosphate Flame Retardants in Indoor Environments[J]. 美国环保署,2018,52(10):5821-5829. |
APA | Liang, Yirui,Liu, Xiaoyu,&Allen, Matthew R..(2018).Measurements of Parameters Controlling the Emissions of Organophosphate Flame Retardants in Indoor Environments.ENVIRONMENTAL SCIENCE & TECHNOLOGY,52(10),5821-5829. |
MLA | Liang, Yirui,et al."Measurements of Parameters Controlling the Emissions of Organophosphate Flame Retardants in Indoor Environments".ENVIRONMENTAL SCIENCE & TECHNOLOGY 52.10(2018):5821-5829. |