CCPortal
DOI10.3390/pr12050904
Performance Enhancement Analysis of Environmentally Friendly Refrigerants
发表日期2024
EISSN2227-9717
起始页码12
结束页码5
卷号12期号:5
英文摘要Due to the impact of global warming and climate change, more and more people are starting to have a clearer understanding and vigilance about greenhouse gases. To prevent further deterioration of the global environment, this study examines the coefficients of performance of 21 currently available refrigerants with very low global-warming potential and zero ozone-depleting potential under evaporation temperatures of 10, -20, -40, and -60 degrees C and condensation temperatures of 30, 40, and 50 degrees C, respectively. It is found that the use of pure refrigerant in a two-stage refrigeration system to replace the single-stage refrigeration system, in addition to mixing it into an appropriate mixture, can effectively improve the performance coefficient of the refrigeration system. For single-stage vapor compression refrigeration systems, R1234ze(Z), R601, and R1233zd(E) have the best refrigeration performances among the environmentally friendly refrigerants studied, while R441A performs the worst for Teva = 10 degrees C and -20 degrees C. Moreover, RE170 has the highest COP of the refrigeration system for Teva = -40 degrees C and -60 degrees C. However, R1234yf performs worse in COP when the evaporation temperature is lower, and it ranks last for Teva = -60 degrees C. When a double-stage vapor compression refrigeration system is employed instead, the percentage increase in the COP of the system using R1234yf becomes the largest for Teva = -40 degrees C and -60 degrees C. However, the growth rate of R717 ranks last for Teva = -60 degrees C. For an R717/R1234yf mixture at an optimum mass fraction of 0.25, the COP of the refrigeration system can be increased up to 25.8% despite an increase of 15.2% in operating pressure compared to R1234yf. The discharge temperature may rise; however, there will be no overheating problem for the compressor.
英文关键词refrigerant; coefficient of performance; evaporation temperature; condensation temperature; global warming potential; ozone depletion potential
语种英语
WOS研究方向Engineering
WOS类目Engineering, Chemical
WOS记录号WOS:001231361900001
来源期刊PROCESSES
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/302403
作者单位National Kaohsiung University of Science & Technology
推荐引用方式
GB/T 7714
. Performance Enhancement Analysis of Environmentally Friendly Refrigerants[J],2024,12(5).
APA (2024).Performance Enhancement Analysis of Environmentally Friendly Refrigerants.PROCESSES,12(5).
MLA "Performance Enhancement Analysis of Environmentally Friendly Refrigerants".PROCESSES 12.5(2024).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
百度学术
百度学术中相似的文章
必应学术
必应学术中相似的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。