CCPortal
DOI10.1016/j.heliyon.2024.e29226
Performance assessment of a refrigeration system with an integrated condenser under different environmental conditions
Banjo, S. O.; Bolaji, B. O.; Oyelaran, O. A.; Babalola, P. O.; Afolalu, A. S.; Salawu, E. Y.; Emetere, M. E.
发表日期2024
EISSN2405-8440
起始页码10
结束页码7
卷号10期号:7
英文摘要This paper presents a workable vapour compression system (VCS) for evaluating the performance of a refrigeration system with an integrated condenser that uses a long-term alternative refrigerant to halocarbon as a heat transfer medium (R600a). India's refrigeration system uses halocarbon refrigerants due to their excellent thermophysical and thermodynamic properties. Greenhouse gas emissions from halocarbon refrigerants and fossil fuel combustion contribute to global warming that engenders climate change and the deterioration of the ecosystem. The halocarbon refrigerant was discontinued based on high global warming potential. The system was investigated under various ambient temperatures of 16, 20, 24, and 28 degrees C (oC). The performance of the VCS was analyzed using the parameters of coefficient performance, compressor work, and pull -down time (PDT). The experimental result shows that the vapour compression system obtained its best PDT, enhanced coefficient of performance, and energy reduction when the ambient temperature was 20 degrees C.
英文关键词Coefficient of performance; Thermal system; Heat exchanger; Environmental control; Vapour compression system
语种英语
WOS研究方向Science & Technology - Other Topics
WOS类目Multidisciplinary Sciences
WOS记录号WOS:001226914500001
来源期刊HELIYON
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/291661
作者单位Covenant University; Covenant University
推荐引用方式
GB/T 7714
Banjo, S. O.,Bolaji, B. O.,Oyelaran, O. A.,et al. Performance assessment of a refrigeration system with an integrated condenser under different environmental conditions[J],2024,10(7).
APA Banjo, S. O..,Bolaji, B. O..,Oyelaran, O. A..,Babalola, P. O..,Afolalu, A. S..,...&Emetere, M. E..(2024).Performance assessment of a refrigeration system with an integrated condenser under different environmental conditions.HELIYON,10(7).
MLA Banjo, S. O.,et al."Performance assessment of a refrigeration system with an integrated condenser under different environmental conditions".HELIYON 10.7(2024).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Banjo, S. O.]的文章
[Bolaji, B. O.]的文章
[Oyelaran, O. A.]的文章
百度学术
百度学术中相似的文章
[Banjo, S. O.]的文章
[Bolaji, B. O.]的文章
[Oyelaran, O. A.]的文章
必应学术
必应学术中相似的文章
[Banjo, S. O.]的文章
[Bolaji, B. O.]的文章
[Oyelaran, O. A.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。