Demonstration of a memory calibration method in water isotope measurement by laser spectroscopy
Qu, Dongmei; Tian, Lide; Zhao, Huabiao; Yao, Ping; Xu, Baiqing; Cui, Jiangpeng
通讯作者Qu, DM (通讯作者)
发表日期2020
ISSN0951-4198
EISSN1097-0231
卷号34期号:8
英文摘要Rationale Measuring delta O-18 and delta H-2 values in water using wavelength-scanned cavity ring down spectroscopy (WS-CRDS) requires multiple injections of up to six (and sometimes eight or more) of one sample to remove the memory effect, which decreases the sample throughput and increases the consumables cost. Thus, improved methods for removing the memory effect are required. Methods We calculated the memory coefficients by sequential WS-CRDS measurement of two lab standard waters with isotopic differences, and used them to establish calibration equations. We then used these equations to correct the measured delta O-18 and delta H-2 values by removing the memory effect, instead of using multiple injections in the routine daily measurements. Results By using this method, the number of injections per sample was reduced to one. The reproducibility (one standard deviation) of the delta O-18 and delta H-2 values obtained for quality control sample was less than 0.05 parts per thousand and 0.5 parts per thousand for an annual average, respectively. Conclusions By measuring the memory coefficients and establishing the calibration equations, a highly effective method was developed for determining the delta O-18 and delta H-2 values of water, which could significantly improve sample throughput for liquid water dual isotope measurement without sacrificing the precision.
关键词LONG-TERM ACCURACYDELTA-O-18DELTA-H-2PRECISIONHYDROGENSAMPLESOXYGEN
语种英语
WOS研究方向Biochemistry & Molecular Biology ; Chemistry ; Spectroscopy
WOS类目Biochemical Research Methods ; Chemistry, Analytical ; Spectroscopy
WOS记录号WOS:000519265300013
来源期刊RAPID COMMUNICATIONS IN MASS SPECTROMETRY
来源机构中国科学院青藏高原研究所
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/259848
推荐引用方式
GB/T 7714
Qu, Dongmei,Tian, Lide,Zhao, Huabiao,et al. Demonstration of a memory calibration method in water isotope measurement by laser spectroscopy[J]. 中国科学院青藏高原研究所,2020,34(8).
APA Qu, Dongmei,Tian, Lide,Zhao, Huabiao,Yao, Ping,Xu, Baiqing,&Cui, Jiangpeng.(2020).Demonstration of a memory calibration method in water isotope measurement by laser spectroscopy.RAPID COMMUNICATIONS IN MASS SPECTROMETRY,34(8).
MLA Qu, Dongmei,et al."Demonstration of a memory calibration method in water isotope measurement by laser spectroscopy".RAPID COMMUNICATIONS IN MASS SPECTROMETRY 34.8(2020).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Qu, Dongmei]的文章
[Tian, Lide]的文章
[Zhao, Huabiao]的文章
百度学术
百度学术中相似的文章
[Qu, Dongmei]的文章
[Tian, Lide]的文章
[Zhao, Huabiao]的文章
必应学术
必应学术中相似的文章
[Qu, Dongmei]的文章
[Tian, Lide]的文章
[Zhao, Huabiao]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。