CCPortal
DOI10.1016/j.talanta.2021.122652
Determination of ultra-trace level plutonium isotopes in soil samples by triple-quadrupole inductively coupled plasma-mass spectrometry with mass-shift mode combined with UTEVA chromatographic separation
Zhang, Weichao; Lin, Jianfeng; Fang, Sui; Li, Chen; Yi, Xiaowei; Hou, Xiaolin; Chen, Ning; Zhang, Haitao; Xu, Yihong; Dang, Haijun; Wang, Wei; Xu, Jiang
通讯作者Zhang, HT ; Dang, HJ (通讯作者),Northwest Inst Nucl Technol, Xian 710024, Peoples R China. ; Xu, YH (通讯作者),Anhui Normal Univ, Sch Geog & Tourism, Key Lab Earth Surface Proc & Reg Response Yangtze, Wuhu 241002, Peoples R China.
发表日期2021
ISSN0039-9140
EISSN1873-3573
卷号234
英文摘要Although triple-quadrupole inductively coupled plasma-mass spectrometry (ICP-MS/MS) has become an attractive technique for the measurement of long-lived radionuclides, the abundance sensitivity, isobaric and polyatomic ions interferences seriously restrict the application. The spectral peak tailing and uranium hydrides (UH+, UH2+) from U-238 have a serious influence on the accurate measurement of Pu-239 and Pu-240, especially for the ultra-trace level plutonium isotopes in the higher uranium sample. A new method was developed using ICPMS/MS measurement in mass-shift mode with collision-reaction gas combined with a chemical separation procedure. As O-2 readily converted Pu+ ion to PuO2+, while disassociated the interfering diatomic ions of interfering elements (U, Pb, Hg, Tl, etc.), the interferences from these elements were completely eliminated if plutonium was detected as PuO2+ at the m/z more than 270. By the mass filter in MS/MS mode combined with O-2 as reaction gas the lower peak tailing of U-238(+) (<5 x 10(-12)) was significantly suppressed. By this way, the (UO2H+)-U-238/(UO2+)-U-238 atomic ratio was reduced to 4.82 x 10(9), which is significantly lower than that of other collision-reaction gas modes. Interferences from Pb, Hg and Tl polyatomic ions were also completely eliminated. Thus, accurate measurement of ultra-trace level 239Pu in high uranium sample solutions with the Pu-239/U-238 concentration ratio of 10(-10) was achieved by the mass-shift mode with 0.15 mL/min O-2/He + 12.0 mL/min He as collision-reaction gas, and high elimination efficiency of uranium interferences up to 10(14) can be obtained by combination with the chemical separation using a single UTEVA resin column. The developed method can be applied to accurately determine the fg level Pu-239 in high uranium samples, such as large-size deep seawater, deep soil and sediment, uranium debris of nuclear fuel.
关键词ENVIRONMENTAL-SAMPLESICP-MSPU ISOTOPESREACTION CELLSEQUENTIAL DETERMINATIONSEDIMENT SAMPLESGLOBAL FALLOUTURANIUMRESOLUTIONPU-240
英文关键词ICP-MS/MS; Collision-reaction cell; Mass-shift mode; Plutonium; Soil sample
语种英语
WOS研究方向Chemistry
WOS类目Chemistry, Analytical
WOS记录号WOS:000687341900007
来源期刊TALANTA
来源机构中国科学院西北生态环境资源研究院
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/254664
作者单位[Zhang, Weichao; Lin, Jianfeng; Fang, Sui; Yi, Xiaowei; Zhang, Haitao; Dang, Haijun; Wang, Wei; Xu, Jiang] Northwest Inst Nucl Technol, Xian 710024, Peoples R China; [Li, Chen; Xu, Yihong] Anhui Normal Univ, Sch Geog & Tourism, Key Lab Earth Surface Proc & Reg Response Yangtze, Wuhu 241002, Peoples R China; [Hou, Xiaolin] Tech Univ Denmark, Dept Environm Engn, Riso Campus, DK-4000 Roskilde, Denmark; [Hou, Xiaolin; Chen, Ning] Chinese Acad Sci, Xian AMS Ctr, Inst Earth Environm, State Key Lab Loess & Quaternary Geol,Shaanxi Key, Xian 710061, Peoples R China
推荐引用方式
GB/T 7714
Zhang, Weichao,Lin, Jianfeng,Fang, Sui,et al. Determination of ultra-trace level plutonium isotopes in soil samples by triple-quadrupole inductively coupled plasma-mass spectrometry with mass-shift mode combined with UTEVA chromatographic separation[J]. 中国科学院西北生态环境资源研究院,2021,234.
APA Zhang, Weichao.,Lin, Jianfeng.,Fang, Sui.,Li, Chen.,Yi, Xiaowei.,...&Xu, Jiang.(2021).Determination of ultra-trace level plutonium isotopes in soil samples by triple-quadrupole inductively coupled plasma-mass spectrometry with mass-shift mode combined with UTEVA chromatographic separation.TALANTA,234.
MLA Zhang, Weichao,et al."Determination of ultra-trace level plutonium isotopes in soil samples by triple-quadrupole inductively coupled plasma-mass spectrometry with mass-shift mode combined with UTEVA chromatographic separation".TALANTA 234(2021).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zhang, Weichao]的文章
[Lin, Jianfeng]的文章
[Fang, Sui]的文章
百度学术
百度学术中相似的文章
[Zhang, Weichao]的文章
[Lin, Jianfeng]的文章
[Fang, Sui]的文章
必应学术
必应学术中相似的文章
[Zhang, Weichao]的文章
[Lin, Jianfeng]的文章
[Fang, Sui]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。