Climate Change Data Portal
DOI | 10.1016/j.atmosenv.2021.118432 |
Calibration of low-cost PurpleAir outdoor monitors using an improved method of calculating PM2.5 | |
Wallace L.; Bi J.; Ott W.R.; Sarnat J.; Liu Y. | |
发表日期 | 2021 |
ISSN | 1352-2310 |
卷号 | 256 |
英文摘要 | PM2.5 hourly average measurements from 33 outdoor PurpleAir particle monitors were compared with hourly measurements from 27 nearby US EPA Air Quality System (AQS) stations employing Federal Equivalent Method (FEM) monitors in California over an 18-month (77-week) period. A transparent and reproducible alternative method (ALT) of calculating PM2.5 from the particle numbers in three size categories was used in place of the estimates provided by Plantower, the manufacturer of the sensors used in PurpleAir monitors. The ALT method was superior in several ways (better precision, lower limit of detection, improved size distribution) compared to Plantower's CF1 or ATM data series. PurpleAir monitors were strongly correlated with the nearby US EPA Air Quality System AQS stations. A calibration factor (CF) ranging between 2.9 and 3.1 was empirically derived for the PurpleAir estimates using the ALT method. This value was based on comparing the average value of 177,329 PurpleAir measurements to the value calculated from the FEM stations. The monitoring period included about 13 weeks showing very high outdoor values due to several major fires covering several hundred thousand acres. The CF during these 13 weeks averaged 2.39, whereas the CF for the remaining 64 weeks averaged about 3.21, suggesting a different response to the smoke from wildfires compared with normal ambient fine particulate matter (PM2.5). The standard Plantower CF1 data series overestimated the FEM values by about 40%, in agreement with several other studies. © 2021 Elsevier Ltd |
关键词 | Calibration factor (CF)Low-cost monitorsPM2.5PurpleAir |
语种 | 英语 |
scopus关键词 | Air quality; Costs; Smoke; Air quality systems; Calibration factor; Calibration factors; Data series; Federal equivalent methods; Low-cost monitor; Low-costs; Particle monitor; PM$-2.5$; Purpleair; Calibration; air quality; ambient air; calibration; numerical model; particulate matter; smoke; air quality; Article; California; concentration (parameter); controlled study; limit of detection; measurement accuracy; particulate matter 2.5; priority journal; reproducibility; smoke; wildfire; California; United States; Varanidae |
来源期刊 | ATMOSPHERIC ENVIRONMENT
![]() |
文献类型 | 期刊论文 |
条目标识符 | http://gcip.llas.ac.cn/handle/2XKMVOVA/248414 |
作者单位 | Independent Researcher, 428 Woodley Way, Santa Rosa, CA 95409, United States; University of Washington, United States; Stanford University, United States; Gangarosa Department of Environmental Health, Rollins School of Public Health, Emory University, Atlanta, GA 30322, United States |
推荐引用方式 GB/T 7714 | Wallace L.,Bi J.,Ott W.R.,et al. Calibration of low-cost PurpleAir outdoor monitors using an improved method of calculating PM2.5[J],2021,256. |
APA | Wallace L.,Bi J.,Ott W.R.,Sarnat J.,&Liu Y..(2021).Calibration of low-cost PurpleAir outdoor monitors using an improved method of calculating PM2.5.ATMOSPHERIC ENVIRONMENT,256. |
MLA | Wallace L.,et al."Calibration of low-cost PurpleAir outdoor monitors using an improved method of calculating PM2.5".ATMOSPHERIC ENVIRONMENT 256(2021). |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Wallace L.]的文章 |
[Bi J.]的文章 |
[Ott W.R.]的文章 |
百度学术 |
百度学术中相似的文章 |
[Wallace L.]的文章 |
[Bi J.]的文章 |
[Ott W.R.]的文章 |
必应学术 |
必应学术中相似的文章 |
[Wallace L.]的文章 |
[Bi J.]的文章 |
[Ott W.R.]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。