CCPortal
DOI10.1016/j.atmosenv.2021.118614
Equivalence of UK nitrogen dioxide diffusion tube data to the EU reference method
Butterfield D.; Martin N.A.; Coppin G.; Fryer D.E.
发表日期2021
ISSN1352-2310
卷号262
英文摘要The UK Government's Department for Environment, Food and Rural Affairs has set up a framework for Local Air Quality Management (LAQM) and Local Authorities widely use nitrogen dioxide (NO2) diffusion tubes for Indicative monitoring to calculate annual NO2 concentrations for Review and Assessment purposes. The European Union under directive 20/50/EC on ambient air quality and cleaner air for Europe provides data quality objectives both for Indicative and Fixed measurements of NO2. LAQM diffusion tube measurements across the UK between 2015 & 2019 were analysed to see if they had been providing data of sufficient quality to be classed as Indicative measurements in support of Local Air Quality Management. Bias corrected annual averaged measurements delivered uncertainties compared to the reference method of <±25%, therefore demonstrating that application of the National bias adjustment factors are providing valid Indicative diffusion tube measurements for the UK. For the full calendar year 2020, the equivalence of the monthly UK Urban NO2 Network (UUNN) diffusion tubes were analysed. The UUNN style diffusion tube is similar to the LAQM style but with the addition of an amorphous polyethylene (PE) filter across the open end of the tube. Results showed that the Network meets the EU Directive uncertainty requirement for Fixed measurements (±15%), without the need for slope or intercept correction. Mean NO2 concentrations derived from triplicate UUNN tubes show a much better precision than the triplicate conventional LAQM tubes. A field determination of the diffusive sampling rate for UUNN tubes was performed at London Marylebone Road, showing that the sampling rate in real world conditions was very similar to that determined in the laboratory. Diffusion tube data form Belgium and Germany were also analysed for equivalence with the Standard Reference Method to help put the UK results into context. © 2021
关键词Ambient airChemiluminescence analyserDiffusive samplingEquivalenceNitrogen dioxide (NO2)
语种英语
scopus关键词Air quality; Diffusion; Nitrogen oxides; Tubes (components); Uncertainty analysis; Air quality management; Ambient air; Chemiluminescence analyser; Diffusion tubes; Diffusive sampling; Nitrogen dioxide (NO2); Nitrogen dioxides; NO $-2$; Reference method; Uncertainty; Quality management; nitrogen dioxide; polyethylene; air quality; air sampling; ambient air; data quality; diffusion; European Union; nitrogen dioxide; air quality; air sampling; ambient air; Article; atmospheric diffusion; Belgium; concentration (parameter); controlled study; England; European Union; Germany; laboratory; measurement precision; total quality management; Belgium; England; Germany; London [England]; United Kingdom
来源期刊ATMOSPHERIC ENVIRONMENT
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/248298
作者单位Air Quality and Aerosol Metrology Group, Atmospheric Environmental Science Department, National Physical Laboratory, Hampton Road, Teddington, Middlesex TW11 0LW, United Kingdom
推荐引用方式
GB/T 7714
Butterfield D.,Martin N.A.,Coppin G.,et al. Equivalence of UK nitrogen dioxide diffusion tube data to the EU reference method[J],2021,262.
APA Butterfield D.,Martin N.A.,Coppin G.,&Fryer D.E..(2021).Equivalence of UK nitrogen dioxide diffusion tube data to the EU reference method.ATMOSPHERIC ENVIRONMENT,262.
MLA Butterfield D.,et al."Equivalence of UK nitrogen dioxide diffusion tube data to the EU reference method".ATMOSPHERIC ENVIRONMENT 262(2021).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Butterfield D.]的文章
[Martin N.A.]的文章
[Coppin G.]的文章
百度学术
百度学术中相似的文章
[Butterfield D.]的文章
[Martin N.A.]的文章
[Coppin G.]的文章
必应学术
必应学术中相似的文章
[Butterfield D.]的文章
[Martin N.A.]的文章
[Coppin G.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。