Climate Change Data Portal
DOI | 10.1016/j.atmosenv.2021.118614 |
Equivalence of UK nitrogen dioxide diffusion tube data to the EU reference method | |
Butterfield D.; Martin N.A.; Coppin G.; Fryer D.E. | |
发表日期 | 2021 |
ISSN | 1352-2310 |
卷号 | 262 |
英文摘要 | The UK Government's Department for Environment, Food and Rural Affairs has set up a framework for Local Air Quality Management (LAQM) and Local Authorities widely use nitrogen dioxide (NO2) diffusion tubes for Indicative monitoring to calculate annual NO2 concentrations for Review and Assessment purposes. The European Union under directive 20/50/EC on ambient air quality and cleaner air for Europe provides data quality objectives both for Indicative and Fixed measurements of NO2. LAQM diffusion tube measurements across the UK between 2015 & 2019 were analysed to see if they had been providing data of sufficient quality to be classed as Indicative measurements in support of Local Air Quality Management. Bias corrected annual averaged measurements delivered uncertainties compared to the reference method of <±25%, therefore demonstrating that application of the National bias adjustment factors are providing valid Indicative diffusion tube measurements for the UK. For the full calendar year 2020, the equivalence of the monthly UK Urban NO2 Network (UUNN) diffusion tubes were analysed. The UUNN style diffusion tube is similar to the LAQM style but with the addition of an amorphous polyethylene (PE) filter across the open end of the tube. Results showed that the Network meets the EU Directive uncertainty requirement for Fixed measurements (±15%), without the need for slope or intercept correction. Mean NO2 concentrations derived from triplicate UUNN tubes show a much better precision than the triplicate conventional LAQM tubes. A field determination of the diffusive sampling rate for UUNN tubes was performed at London Marylebone Road, showing that the sampling rate in real world conditions was very similar to that determined in the laboratory. Diffusion tube data form Belgium and Germany were also analysed for equivalence with the Standard Reference Method to help put the UK results into context. © 2021 |
关键词 | Ambient airChemiluminescence analyserDiffusive samplingEquivalenceNitrogen dioxide (NO2) |
语种 | 英语 |
scopus关键词 | Air quality; Diffusion; Nitrogen oxides; Tubes (components); Uncertainty analysis; Air quality management; Ambient air; Chemiluminescence analyser; Diffusion tubes; Diffusive sampling; Nitrogen dioxide (NO2); Nitrogen dioxides; NO $-2$; Reference method; Uncertainty; Quality management; nitrogen dioxide; polyethylene; air quality; air sampling; ambient air; data quality; diffusion; European Union; nitrogen dioxide; air quality; air sampling; ambient air; Article; atmospheric diffusion; Belgium; concentration (parameter); controlled study; England; European Union; Germany; laboratory; measurement precision; total quality management; Belgium; England; Germany; London [England]; United Kingdom |
来源期刊 | ATMOSPHERIC ENVIRONMENT |
文献类型 | 期刊论文 |
条目标识符 | http://gcip.llas.ac.cn/handle/2XKMVOVA/248298 |
作者单位 | Air Quality and Aerosol Metrology Group, Atmospheric Environmental Science Department, National Physical Laboratory, Hampton Road, Teddington, Middlesex TW11 0LW, United Kingdom |
推荐引用方式 GB/T 7714 | Butterfield D.,Martin N.A.,Coppin G.,et al. Equivalence of UK nitrogen dioxide diffusion tube data to the EU reference method[J],2021,262. |
APA | Butterfield D.,Martin N.A.,Coppin G.,&Fryer D.E..(2021).Equivalence of UK nitrogen dioxide diffusion tube data to the EU reference method.ATMOSPHERIC ENVIRONMENT,262. |
MLA | Butterfield D.,et al."Equivalence of UK nitrogen dioxide diffusion tube data to the EU reference method".ATMOSPHERIC ENVIRONMENT 262(2021). |
条目包含的文件 | 条目无相关文件。 |