Prevention and control of abnormal gas emission caused by accidental discharge of floor fissure water: a case study
Gao Z.-S.; Zhu C.-J.; Lu X.-M.; Ren J.
发表日期2020
ISSN0921030X
起始页码713
结束页码733
卷号100期号:2
英文摘要Gas (coalbed methane) and fissure water often coexist in coal-bearing strata, and gas is sealed in adjacent rock strata by fissure water in some coal mines. After the fissure water is discharged, abnormal gas emission may occur due to accidental release of large amount of sealed gas. In the present work, abnormal gas emission caused by accidental discharge of floor fissure water occurred at Tangjiahe Coal Mine (Guangyuan, China), and its control method was discussed. Sealing technology, uniform pressure ventilation and gas drainage for intercepting gas by cross-boreholes were adopted to solve abnormal gas emission. Firstly, several sealings were constructed to seal gobs full of high-concentration gas, which prevented gas diffusion and spread into mining space. Two gas extraction systems were installed, and uniform pressure ventilation was applied to eliminate fissure gas accumulated in gobs. Subsequently, a comprehensive recovery of ventilation was realized. As a supplementary measure, downward cross-boreholes were drilled to prevent gas from releasing into mining space. © 2019, Springer Nature B.V.
关键词Abnormal gas emissionFissure waterGas controlGas drainageUniform pressure ventilation
英文关键词coal mine; coalbed methane; degassing; drilling; fissure; gas flow; pressure field; sealing; ventilation; China; Guangyuan; Sichuan
语种英语
来源期刊Natural Hazards
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/205699
作者单位Faculty of Safety Engineering, China University of Mining and Technology, Xuzhou, Jiangsu 221116, China
推荐引用方式
GB/T 7714
Gao Z.-S.,Zhu C.-J.,Lu X.-M.,et al. Prevention and control of abnormal gas emission caused by accidental discharge of floor fissure water: a case study[J],2020,100(2).
APA Gao Z.-S.,Zhu C.-J.,Lu X.-M.,&Ren J..(2020).Prevention and control of abnormal gas emission caused by accidental discharge of floor fissure water: a case study.Natural Hazards,100(2).
MLA Gao Z.-S.,et al."Prevention and control of abnormal gas emission caused by accidental discharge of floor fissure water: a case study".Natural Hazards 100.2(2020).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Gao Z.-S.]的文章
[Zhu C.-J.]的文章
[Lu X.-M.]的文章
百度学术
百度学术中相似的文章
[Gao Z.-S.]的文章
[Zhu C.-J.]的文章
[Lu X.-M.]的文章
必应学术
必应学术中相似的文章
[Gao Z.-S.]的文章
[Zhu C.-J.]的文章
[Lu X.-M.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。