What does the GB power outage on 9 August 2019 tell us about the current state of decarbonised power systems?
Bialek J.
发表日期2020
ISSN03014215
卷号146
英文摘要The GB power blackout, that happened on 9 August 2019, was a unique stress test exposing fault lines brought about by the rapid changes due to the decarbonisation drive and penetration of smart grids technologies. It has demonstrated that, as a significant amount of new equipment and controls were added to the system in a very short time, the probability of common, hidden modes of failures has significantly increased. In the face of declining reliability, maintaining the status quo is not an option. While currently increasing the (N-1) security margin could prove to be expensive, the balance of costs and benefits is likely to change in future. Especially wider application of innovative frequency controls, including “virtual inertia” and Remedial Action Schemes, could help reduce the costs. Distributed Generation (DG) reached such a high penetration level that it cannot be treated any longer as negative demand. Traditional under-frequency load shedding should be made more selective. Interactions between the power system and other infrastructures are still poorly understood and there is a significant risk that if the current compartmentalised approach to their governance and operation is not changed, we may see more unexpected consequences of disturbances across the whole system. © 2020
关键词DecarbonisationPower blackoutsReliability standards
英文关键词Electric load shedding; Electric power transmission networks; Smart power grids; Costs and benefits; Decarbonisation; Negative demands; Penetration level; Power blackout; Remedial action scheme; Security margins; Underfrequency load-shedding; Outages; carbon emission; emission control; infrastructure; smart grid; technology
语种英语
来源期刊Energy Policy
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/204570
作者单位Newcastle University, Merz Court, Newcastle upon Tyne, NE1 7RU, United Kingdom; Skolkovo Institute of Science and Technology (Skoltech), Bolshoy Boulevard 30, bld. 1, Moscow, 121205, Russian Federation
推荐引用方式
GB/T 7714
Bialek J.. What does the GB power outage on 9 August 2019 tell us about the current state of decarbonised power systems?[J],2020,146.
APA Bialek J..(2020).What does the GB power outage on 9 August 2019 tell us about the current state of decarbonised power systems?.Energy Policy,146.
MLA Bialek J.."What does the GB power outage on 9 August 2019 tell us about the current state of decarbonised power systems?".Energy Policy 146(2020).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Bialek J.]的文章
百度学术
百度学术中相似的文章
[Bialek J.]的文章
必应学术
必应学术中相似的文章
[Bialek J.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。