CCPortal
DOI10.3390/infrastructures5120114
Design corrections in spanish office buildings to improve energy efficiency in the face of climate change
Orosa J.A.; Vergara D.; Fraguela F.; Fernández-Arias P.
发表日期2020
ISSN24123811
起始页码1
结束页码13
卷号5期号:12
英文摘要The majority of buildings in Europe are at present naturally ventilated and do not use heating or cooling equipment throughout the summer. However, this idea is changing and as a result heating ventilation air conditioning (HVAC) related energy consumption has been rising in the recent years. On the other hand, predictions published by the intergovernmental Panel on Climate Change (IPCC) indicate an annual warming rate ranging between 0.1 and 0.4◦C. In the present study, the ISO 13790:2011 standard has been employed to analyze the effect of building design corrections over the energy saving of a real building during its mean life and under climatic change predictions. In this sense, the effect of climate change, ventilation rate and its energetic and carbon dioxide emissions implications are obtained for the next 15 years. The results obtained indicate that an increment in the air changes by natural ventilation will be more effective than changing the wall structure and, in consequence, the thermal inertia. In particular, it was obtained that an increase of natural ventilation will always reduce the energy consumption and that this consumption will be lower with time due to an increment of an average outdoor air temperature. This modification will allow reduced cooling energy peak demands during the summer season and improve indoor ambiences in mild regions and the energy efficiency. © 2020 by the authors. Licensee MDPI, Basel, Switzerland.
英文关键词Climate change; Design corrections; Energy consumption; Energy efficiency; Office buildings
来源期刊Infrastructures
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/176738
作者单位Department of N. S. and Marine Engineering, Universidade da Coruña, Paseo de Ronda, 51, Coruña, 15011 A, Spain; Department of Mechanical Engineering, Catholic University of Ávila, C/Canteros, s/n, Avila, 05005, Spain
推荐引用方式
GB/T 7714
Orosa J.A.,Vergara D.,Fraguela F.,et al. Design corrections in spanish office buildings to improve energy efficiency in the face of climate change[J],2020,5(12).
APA Orosa J.A.,Vergara D.,Fraguela F.,&Fernández-Arias P..(2020).Design corrections in spanish office buildings to improve energy efficiency in the face of climate change.Infrastructures,5(12).
MLA Orosa J.A.,et al."Design corrections in spanish office buildings to improve energy efficiency in the face of climate change".Infrastructures 5.12(2020).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Orosa J.A.]的文章
[Vergara D.]的文章
[Fraguela F.]的文章
百度学术
百度学术中相似的文章
[Orosa J.A.]的文章
[Vergara D.]的文章
[Fraguela F.]的文章
必应学术
必应学术中相似的文章
[Orosa J.A.]的文章
[Vergara D.]的文章
[Fraguela F.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。