Climate Change Data Portal
DOI | 10.5194/acp-19-5005-2019 |
Identification of soil-cooling rains in southern France from soil temperature and soil moisture observations | |
Zhang S.; Meurey C.; Calvet J.-C. | |
发表日期 | 2019 |
ISSN | 16807316 |
起始页码 | 5005 |
结束页码 | 5020 |
卷号 | 19期号:7 |
英文摘要 | In this study, the frequency and intensity of soil-cooling rains is assessed using in situ observations of atmospheric and soil profile variables in southern France. Rainfall, soil temperature, and topsoil volumetric soil moisture (VSM) observations, measured every 12 min at 21 stations of the SMOSMANIA (Soil Moisture Observing System - Meteorological Automatic Network Integrated Application) network, are analyzed over a time period of 9 years, from 2008 to 2016. The spatial and temporal statistical distribution of the observed rainfall events presenting a marked soil-cooling effect is investigated. It is observed that the soil temperature at a depth of 5 cm can decrease by as much as 6.5C in only 12 min during a soil-cooling rain. We define marked soil-cooling rains as rainfall events triggering a drop in soil temperature at a depth of 5cm larger than 1.5C in 12min. Under Mediterranean and Mediterranean-mountain climates, it is shown that such events occur up to nearly 3 times a year, and about once a year on average. This frequency decreases to about once every 3.5 years under semi-oceanic climate. Under oceanic climate, such pronounced soil-cooling rains are not observed over the considered period of time. Rainwater temperature is estimated for 13 cases of marked soil-cooling rains using observed changes within 12min in soil temperature at a depth of 5cm, together with soil thermal properties and changes in VSM. On average, the estimated rainwater temperature is generally lower than the observed ambient air temperature, wet-bulb temperature, and topsoil temperature at a depth of 5cm, with mean differences of ĝ'5.1C, respectively. The most pronounced differences are attributed to hailstorms or to hailstones melting before getting to the soil surface. Ignoring this cooling effect can introduce biases in land surface energy budget simulations. © Author(s) 2019. |
语种 | 英语 |
scopus关键词 | cooling; energy budget; land surface; observational method; precipitation intensity; soil moisture; soil profile; soil property; soil temperature; thermodynamic property; France |
来源期刊 | Atmospheric Chemistry and Physics
![]() |
文献类型 | 期刊论文 |
条目标识符 | http://gcip.llas.ac.cn/handle/2XKMVOVA/144487 |
作者单位 | CNRM, Université de Toulouse Météo-France, CNRS, Toulouse, France; Qian Xuesen Laboratory of Space Technology, China Academy of Space Technology (CAST), Beijing, China |
推荐引用方式 GB/T 7714 | Zhang S.,Meurey C.,Calvet J.-C.. Identification of soil-cooling rains in southern France from soil temperature and soil moisture observations[J],2019,19(7). |
APA | Zhang S.,Meurey C.,&Calvet J.-C..(2019).Identification of soil-cooling rains in southern France from soil temperature and soil moisture observations.Atmospheric Chemistry and Physics,19(7). |
MLA | Zhang S.,et al."Identification of soil-cooling rains in southern France from soil temperature and soil moisture observations".Atmospheric Chemistry and Physics 19.7(2019). |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。