Performance analysis of a combined cold and power (CCP) system with exergy recovery from LNG-regasification
Atienza-Marquez, Antonio1; Caries Bruno, Joan1; Akisawa, Atsushi2; Coronas, Alberto1
发表日期2019
ISSN0360-5442
EISSN1873-6785
卷号183页码:448-461
英文摘要

Liquefied Natural Gas (LNG) is becoming vital in relation to energy transition and fighting climate change. Because of its cryogenic temperature (111 K), LNG is an exergy "mine" that can be exploited in the regasification process for multiple industrial applications. But this exergy is usually wasted.


This research presents a Combined Cold and Power (CCP) system with exergy recovery from LNG-regasification. This exergy is exploited for the combined production of electricity and low-temperature refrigeration distributed through a CO2 District Cooling Network. These systems entail many benefits, but also pending challenges. The CCP system is modelled using real operation data, and its performance is analyzed and benchmarked against that of a cryogenic power plant, both at design and off-design operating conditions.


The proposed CCP system reports an equivalent electricity saving of 139 kWh/t-LNG with an exergetic efficiency of 40%, turning into useful energy up to 64% of the maximum cold recoverable in the regasification process. The performance enhances as the heat source temperature rises. Higher LNG flow rates contribute to increase the electricity and refrigeration production, but irreversibilities also increase. Finally, findings show that a low LNG regasification pressure is preferable in spite of the negative effect on the power generation. (C) 2019 Elsevier Ltd. All rights reserved.


WOS研究方向Thermodynamics ; Energy & Fuels
来源期刊ENERGY
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/102898
作者单位1.Univ Rovira & Virgili, CREVER Grp Appl Thermal Engn, Dept Mech Engn, Ave Paisos Catalans 26, E-43007 Tarragona, Spain;
2.Tokyo Univ Agr & Technol, Grad Sch Bioapplicat & Syst Engn, 2-24-16 Nakacho, Koganei, Tokyo 1848588, Japan
推荐引用方式
GB/T 7714
Atienza-Marquez, Antonio,Caries Bruno, Joan,Akisawa, Atsushi,et al. Performance analysis of a combined cold and power (CCP) system with exergy recovery from LNG-regasification[J],2019,183:448-461.
APA Atienza-Marquez, Antonio,Caries Bruno, Joan,Akisawa, Atsushi,&Coronas, Alberto.(2019).Performance analysis of a combined cold and power (CCP) system with exergy recovery from LNG-regasification.ENERGY,183,448-461.
MLA Atienza-Marquez, Antonio,et al."Performance analysis of a combined cold and power (CCP) system with exergy recovery from LNG-regasification".ENERGY 183(2019):448-461.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Atienza-Marquez, Antonio]的文章
[Caries Bruno, Joan]的文章
[Akisawa, Atsushi]的文章
百度学术
百度学术中相似的文章
[Atienza-Marquez, Antonio]的文章
[Caries Bruno, Joan]的文章
[Akisawa, Atsushi]的文章
必应学术
必应学术中相似的文章
[Atienza-Marquez, Antonio]的文章
[Caries Bruno, Joan]的文章
[Akisawa, Atsushi]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。